Technical Specifications
Control Unit
Range: User selectable 0-10 ppm to 0-5,000 ppm minimum alarm set point 3 ppm
Display Resolution: 0.1 ppm
Instrument Accuracy: +/- 0.1 ppm
Process Accuracy: +/- 1.0 ppm under stable conditions
Oil Type: All PAH hydrocarbons, free and dissolved
Sensitivity: 145 ppb diesel reference; 463 ppb crude reference
Ambient Operating Temp.: 5°C to 50°C (best accuracy between 10°C to 40°C); Protect from direct sun or rain. Instrument shelter or indoor use is recommended. Air Conditioners available.
Ambient Process Temp.: 0°C to 40°C (optional cooler for temperatures >40°C)
Power Input: 24 vdc or 100–240 vac, S.P.
Alarm Relays: 4 x 10 amp, SPDT, dry
Output: 4-20 mA, Isolated
Interface: RS-485 standard (optional HART and FF modules)
Certifications: CSA SPE-1000; Canadian Electrical Code (CEC); USA National Electrical Code (NEC)
Enclosure: 316 SS, Type 4X, IP65
Features & Benefits
• The special UV absorbing flow plate sheens the water over a large surface area. The resulting high surface area to depth ratio provides many benefits.
• The sensitivity to oil molecules is increased by maximizing the optical viewing area
• The minimal depth discourages oil molecules from ‘hiding’ behind particulates in the water
• The large lamp source targets the water from multiple angles to get a representative sampling of all oil
• The large sample target area ensures a representative and stable snapshot of the water conditions
• The unit can tolerate suspended solids up to 400 mg/lnon-contacting optics minimizes maintenance
• Non-contacting sensor design minimizes system maintenance
• Fluorescence technology is selective to petroleum hydrocarbons by targeting their aromatic faction
• Continuous on-line monitoring without chemicals or lag time
• Compensation for temperature and lamp degradation minimizes recalibration requirements
• Alarm warns of impending lamp replacement
• Long life lamp expectancy of 18 months
• Continuous on-line monitoring reads the water 50 times/second with an averaged display update every one second
• No consumables or chemical used
• Sample flow gravity outfalls to drain
• Available with CSA Zone 2 approval or with NFPA/ATEX Pressurization Systems for Zone 2
• Designed for harsh environments with a 316 SS housing
• No tools necessary for routine maintenance or lamp replacement
• The flow or power does not require to be turned off during routine maintenance
• Flow chamber diversion system conditions and clarifies sample
• Multi-point calibration available to customize response curves
• Overflow baffle de-aerates bubbles
• Certified to IMO MPEC.107(49) when interfaced with site logging and by-pass requirements
Overview
The HydroSense 4410-LMP Oil in Water Analyser offers continuous on-line monitoring for ppm concentrations of petroleum oils in effluent and produced water without chemicals or lag time. A non-contacting sensor design minimizes system maintenance. The 4410-LMP is the engineered combination of three unique designs: